Technical data
Nominal voltage: 400 V 3 N AC 50 Hz
Switching load: max. 9 kW Ohm resistive load (AC1 - mode)
Air conditioning mode: 6 kW + 3 kW for vaporiser device
can be extended by connecting powered control units
up to 36 kW
Heating time limit: 6 hr, 12 hr or no heating time limit
Display: Jumbo backlit LCD
Protection class: IPx4 in line with EN 60529 splashed water resistant
Normal range for sauna: 30 to 110°C
Normal range for humid mode: 30 to 70°C
With humidity-control
without humidity sensor: me/proportional vaporizing control.
Sensor system: KTY sensor with safety temperature limiter 142°C
Water level monitoring: A lack of water in the vaporiser results in automatic shut
down after two minutes Lack of water.
Control characteristic: digital two-point regulation
Fan output: min. 25W
max.100 W max. 500 mA (only fan excluding
capacitor)
Light: min. 25W max. 100W max. 500 mA (Only ohm resi-
stive load, we recommendto use special bulbs like baking
oven bulbs. Other lamps have to use with the optional
control modules.).
Coloured light (optional): max. 100 W per colour
Colour on-time: 1 - 10 min
Colour order: red - red/yellow - yellow - yellow/green - green - green/blue
- blue - blue/red
Reheatingtime: 0 - 60 min after switching off humidity program
Error display: via warning triangle (fl ashing) and error code on LCD
Ambient temperatures: -10°C to +35°C
Storage temperatures: -20°C to +60°C
Fuse protection on the light and the ventilation can be
a maximum of 0,5 A delay action. There is a danger
of fi re if greater fuse protection is used!