41
NO.
Instruction
Setting
20
Dry contact
OFF voltage
User define for the 24V system: 21.6~32.0V
Step size: long press for 1V, short press for 0.1V
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V, short press for 0.1V
21
Maximum
charging
current
UP3000-HM5041/UP3000-HM5042:
50A(Default) User define: 5~50A
UP2000-HM6021/UP2000-HM6022:
60A(Default) User define: 5~60A
UP3000-HM10021/UP3000-HM10022:
100A(Default) User define: 5~100A
UP3000-HM8041/UP5000-HM8042:
80A(Default) User define: 5~80A
Step size: long press for 10Ashort press for 1A
22
Max. utility
charging
current
UP2000-HM6021/UP2000-HM6022/UP5000-
HM8042: 60A(Default) User define: 2~60A
UP3000-HM5041/UP3000-HM5042/UP3000-
HM8041: 40A(Default) User define: 2~40A
UP3000-HM10021/UP3000-HM10022:
80A(Default) User define: 2~80A
Step size: long press for 10A, short press for 1A
24
Clear fault
OFF(Default)
ON
25
Clear the PV
accumulated
energy
OFF(Default)
ON
26
Total battery
capacity
100AH(Default)
User define:1~4000AH
Step size:
Below 200AH: long press for 10A, short press for
1A
Above 200AH: long press for 50A, short press for
5A
CAUTION: To accurately display the battery capacity,
the customer needs to set this item according to the
actual battery capacity.