42
NO.
Instruction
Setting
27
Temperature
compensate
coefficient
3(Default)
0(lithium battery)
0~9(Non-lithium battery)
Step size is 1
28
Charge low
temperature
limit
0(Default)
User define:-40~0
Step size: 5
29
Discharge low
temperature
limit
0(Default)
User define:-40~0
Step size: 5
30
Output voltage
level
110VAC(Default for devices of 100V output
voltage)
120VAC
220VAC(Default for devices of 200V output
voltage)
230VAC
31
Output
frequency
(If detecting the
utility input, the
output
frequency is
switched to the
utility frequency
automatically.)
50Hz(Default)
60Hz
32
Lithium battery
protection
enable(stop
charging and
discharging the
lithium battery
when the
temperature is
too low)
OFF(Default)
ON
(Note: After connecting to the BMS successfully, it
will be ON status automatically.)