EasyManua.ls Logo

Epever UP2000-HM6021 - Page 45

Epever UP2000-HM6021
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
NO.
Instruction
Setting
33
Charge voltage
limit voltage
User define for the 24V system:
21.6~32.0V
Step size: long press for 1V, short press for
0.1V
AGM(Default)/GEL/FLD: 30.0V
LFP8: 28.5V
LNCM7: 29.4V
User define for the 48V system:
43.2~64.0V
Step size: long press for 1V, short press for
0.1V
AGM(Default)/GEL/FLD: 60.0V
LFP15: 53.5V
LFP16: 57.0V
LNCM14: 58.8V
35
Under voltage
reconnect
voltage
User define for the 24V system:
21.6~32.0V
Step size: long press for 1V, short press for
0.1V
AGM(Default)/GEL/FLD: 24.4V
LFP8: 26.2V
LNCM7: 26.7V
User define for the 48V system:
43.2~64.0V
Step size: long press for 1V, short press for
0.1V
AGM(Default)/GEL/FLD: 48.8V
LFP15: 49.2V
LFP16: 52.4V
LNCM14: 53.4V
36
Under voltage
warning voltage
User define for the 24V system:
21.6~32.0V
Step size: long press for 1V, short press for
0.1V
AGM(Default)/GEL/FLD: 24.0V
LFP8: 25.7V
LNCM7: 26.2V
User define for the 48V system:
43.2~64.0V
Step size: long press for 1V, short press for
0.1V
AGM(Default)/GEL/FLD: 48.0V
LFP15: 48.2V
LFP16: 51.4V
LNCM14: 52.4V

Related product manuals