EasyManuals Logo

Epson EB-U50 User Manual

Epson EB-U50
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Projector Network Settings - Network Menu
141
Setting Options Description
IPv6 Settings Select the IPv6 settings if you want to
connect the projector to the network
using IPv6:
IPv6 IPv6: set to On if you want to connect
the projector to the network using IPv6.
IPv6 is supported to monitor and control
the projector over a network using Epson
Web Control and PJLink.
Auto Configuration Auto Configuration: set to On to assign
addresses automatically according to the
Router Advertisement.
Use Temporary
Address
Use Temporary Address: set to On if
you want to use a temporary IPv6
address.
Network Menu - Notifications Menu
Settings on the Notifications menu let you receive an email notification if a
problem or warning occurs in the projector.
s Network > Network Configuration > Notifications
Setting Options Description
Mail Notification On
Off
Set to On to send an email to the preset
addresses when a problem or warning
occurs with a projector.
SMTP Server IP address Enter the IP address for the projector's
SMTP server using 0 to 255 for each
address field.
Do not use these addresses: 127.x.x.x,
192.0.2.x or 224.0.0.0 through
255.255.255.255 (where x is a number
from 0 to 255).
Port Number 0 to 65535 (default
is 25)
Select a number for the SMTP server
Port Number.
From Up to 32
alphanumeric
characters
Up to 64
alphanumeric
characters from the
Web browser
(do not use " ( ) , : ;
< > [ \] spaces)
Enter the email address of the sender.
Address 1 Setting
Address 2 Setting
Address 3 Setting
Enter the e-mail address, and select the
alerts you want to receive. Repeat for up
to 3 addresses.
SNMP On
Off
Set to On to monitor the projector using
SNMP. To monitor the projector, you
need to install the SNMP manager
program on your computer. SNMP
should be managed by a network
administrator.
Trap IP Address 1
Trap IP Address 2
IP address Enter up to two IP addresses to receive
SNMP notifications, using 0 to 255 for
each address field.
Do not use these addresses: 127.x.x.x or
224.0.0.0 through 255.255.255.255
(where x is a number from 0 to 255).

Table of Contents

Other manuals for Epson EB-U50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson EB-U50 and is the answer not in the manual?

Epson EB-U50 Specifications

General IconGeneral
BrandEpson
ModelEB-U50
CategoryProjector
LanguageEnglish

Related product manuals