Item Parameter Explanation
Media Adjust
Select this option to adjust media with Auto Media Adjust disabled or
make readjustment when changing printing conditions after saving
media settings.
In this menu, perform Feed Adjustment and Head Alignment
individually.
Adjustment types and execution procedure U “Media Adjust” on
page 86
Feed Adjustment
Auto Print
Manual Print
Head Alignment
Standard
(Auto)
Print
Standard
(Manual)
Print
Block pattern Manual(Uni-D)
Manual(Bi-D)
Manual(Dual Head)
*1
Heating & Drying
Heater Tempera-
ture
Pre-heater/platen
heater: 30˚C to 50˚C
(86˚F to 122˚F)
After heater: 30˚C to
55˚C (86˚F to 131˚F)
The temperatures for the pre-, platen, and after heaters can each be
adjusted separately.
Drying Time Per
Pass
0 to 10 sec Select the time the print head pauses to allow drying after each pass.
Choose from values between 0.0 and 10.0 seconds. The time needed for
the ink to dry varies with ink density and the media used. If the ink blurs on
the media, set a longer time for drying the ink.
Increasing the drying time increases the time needed to print.
After Heater Feed Mode 1
To feed media to the after heater after printing, choose Mode 1 or Mode 2;
otherwise, choose Off.
If Mode 1 is selected, the portion fed for drying will not be rewound before
the next job starts. Select this option if the media will be cut before the next
job starts.
If Mode 2 is selected, the portion fed for drying will be rewound before the
next job starts, eliminating unnecessary margin. Select this option if
multiple jobs will be printed consecutively.
Mode 2
Off
Additional Dryer
On This item is displayed only when the additional print drying system
(supplied with the SC-S50600 series; optional with other models) is
installed.
Select On to enable, or Off to disable, the additional print drying system
(supplied with the SC-S50600 series; optional with other models). Note
that even when On is selected, the additional print drying system will turn
off with the heaters when the Heat Off Timer expires. The additional print
drying system will turn back on when the heaters resume operation. Heat
Off TimerU “The Printer Setup Menu” on page 149
Off
Advanced Settings During general use, use the default setting value without changing it.
When using special media or when a problem such as head striking or
banding is detected in printing results, change the default.
EPSON SC-S70600 series/SC-S50600 series/SC-S30600 series User's Guide
Using the Control Panel Menu
147