EPSON Stylus Photo R220/R230 Revision A
ADJUSTMENT Adjustment Except Adjustment Program 94
9. After finishing PG Adjustment on the right, move the Carriage Unit to the left
edge of the printer again, then check PG according to the flowchart in the Figure
3-11.
Figure 3-11. PG Checking (1)
10. Move the Carriage Unit back to the left edge of the printer, then set the Thickness
Gauge (1.31mm) on the three ribs of the Paper Guide, Front in the same way as the
Figure 3-7.
11. Check PGs on both the left and right according to the flowchart in the Figure 3-12.
Figure 3-12. PG Checking (2)
12. After finishing the adjustment, secure the Bushing, Parallel Adjust, Left (Right)
with screws.
13. After securing, check PGs on both the left and right again according to the
flowchart in the Figure 3-12.
Yes
No
Take up: PG gets wider
Take down: PG gets narrower
Go to Step 10
Start
Take up the Bushing,
Parallel Adjust, Left toward
the printer back by 1 notch.
Move the Carriage Unit to
the right by using the
Timing Belt.
Does the Thickness
Gauge move?
Yes
No
Move the Carriage Unit
from side to side on the
Thickness Gauge by using
the Timing Belt.
Does the Thickness
Gauge move?
Go Back to Step 7
Note: Take down toward the printer front by 1 notch:
PG gets narrower.
Take up toward the printer back by 1 notch:
PG gets wider.
No
Yes
Start
Go Back to Step 3
Check left PG.
No
Yes
Check right PG.
Go to Step 12
Move the Carriage Unit
from side to side on the
Thickness Gauge by using
the Timing Belt.
Does the Thickness
Gauge move?
Move the Carriage Unit
from side to side on the
Thickness Gauge by using
the Timing Belt.
Does the Thickness
Gauge move?