Safety information for dismantling and assembly
6/58
2 Safety information for dismantling and assembly
DANGER!
Electricity throughout entire device!
Installation and electrical connections must
comply with the national regulations, in
Germany VDE regulations.
The electrical installation is to be fitted with an
easily accessible all pole isolating device (mas-
ter switch) on the building side, complying with
overvoltage category III. This means that each
pin shall have a contact opening width comply-
ing with the conditions of overvoltage category
III for full isolation.
If the connection is carried out using a plug
connection, a plug system should be used that
corresponds with the current EN 60309 version.
Assembly, installation, upgrading or repair of
the device may only be carried out by specially
trained and instructed personnel.
– All danger and safety notes attached to the
device must be observed!
– No safety equipment (e.g. panel switch) or
safety warnings may be removed or deac-
tivated which would impair the safe opera-
tion of the device!
– The device may only be assigned to the
studio operator in full working order!
– Assembly is only permitted following the
prescribed stages in these Installation in-
structions!
– In all dismantling and assembly work on
electrical systems, the device is to be dis-
connected from the power supply (see
page Fehler! Textmarke nicht definiert.).
Exceptions are permissible only for function
tests!
– A timer must be installed so that the unit is
automatically switched off at the latest af-
ter <110% of the selected operating time
even when the controller fails. The device
operating time must therefore have dual
regulation by means of a timer, as set forth
in EN 60335-2-27.
– Do not change, obstruct or block the air
inflow and outflow area to the device or
make any unauthorized changes to the de-
vice. The manufacturer shall bear no liability
for damage or injuries resulting from such