EMC Capabilities for RBS 2301
Limit standard VDE 0878, Conducted emission, part 1
Limit Class B
Table 31 Interference on DC power supply leads
Basic standard EN 50 022 and proposed amendment to CISPR 22
Limit Class B
Limit standard ETS 300 342-2, Nov 1994
Limit Class B
Table 32 Interference on signal and telecommunication lines
Basic standard CISPR/G(sec) December 1993
39.3.3 Radiated Emission from Enclosure
Table 33 Electric field emission
Basic standard EN 55 022
Limit Class B
Table 34 Magnetic field emission
Limit standard VDE 0878, Magnetic emission, part 1
Limit Class B
39.3.4 Conducted Immunity on AC Input Power Ports
Table 35 Fast transient test
Basic standard IEC 1000-4-4
Test level 6 kV common mode between all lines and cabinet ground reference
Performance Criteria B
Limit standard ETS 300 342-2
Test level 6 kV common mode between all lines and cabinet ground reference
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units