EMC Capabilities for RBS 2301
Table 36 Surge test
Limit standard ETS 300 342-2
Test level 6 kV common mode between all lines and cabinet ground
reference
1)
6 kV differential mode, between line and line
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
1)
System primary protected
Table 37 RF common mode test
Limit standard ETS 300 342-2
Test level 10 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
Table 38 Voltage dips and interruptions on AC ports
Basic standard IEC 1000-4-11
Performance Criteria A for a complete system
39.3.5 Immunity on Telecommunication and External Signal Lines
Table 39 Fast transient test
Basic standard IEC 1000-4-4
Test level 2 kV common mode between line and cabinet ground reference
Performance Criteria B
Limit standard ETS 300 342-2
Test level 4 kV common mode between line and cabinet ground reference
Performance Criteria A for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 40 Surge test 1.2/50 pulses
Limit standard IEC 1000-4-5
Test level 2 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
260 (306)
EN/LZT 123 2697 R5A