EMC Capabilities for RBS 2301
Table 41 Surge test 10/700 pulses
Limit standard IEC 1000-4-5
Test level 1 kV common mode between line and cabinet ground reference
1 kV differential mode between line and line
Performance Criteria B for a complete system
Criteria TT for transmitter units
Criteria TR for receiver units
Table 42 Power induction test
Basic standard ITU-T K.20
Test level 600 V(rms) common mode
Performance Criteria A(K.20)
Table 43 RF common mode test
Limit standard ETS 300 342-2
Test level 10 V(rms)
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
39.3.6 Radiated Immunity of Enclosure Port
Table 44 Immunity of continuous electric fields
Basic standard IEC 801-3
Test level 10 V/m
Performance Criteria A
Limit standard ETS 300 342-2
Test level 10 V/m, 80 MHz - 1 GHz
Frequency range 30 V/m, 1 GHz-20 GHz
Performance Criteria A for a complete system
Criteria CT for transmitter units
Criteria CR for receiver units
Table 45 Immunity of 50/60 Hz magnetic fields
Basic standard IEC 1000-4-8
Test level 10 A/m, 50/60 Hz
Performance Criteria A
EN/LZT 123 2697 R5A
1998-08-13
261 (306)
© Ericsson Radio Systems AB
— All Rights Reserved —