BTS Parameter Limitations
44.4.13 IS Connection List
BTS-supported value range:
ICP: 4 - 127
(dec)
256 - 351
(dec)
512 - 711
(dec)
CI: 1 - 72
(dec)
The IWD-defined value ranges:
ICP: 0 - 1023
(dec)
CI: 1 - 255
(dec)
Note: There are limitations for specific combinations. For more
information see figure in appendix.
44.4.14 Local Access State
BTS-supported value range:
Local Access State parameter: 0
IWD-defined value range: 0 - 1
44.4.15 MO Identifier
Table 82 BTS-supported/IWD-defined value range
MO class BTS-supported value (hex) IWD-defined value (hex)
Instance number Instance number
TRXC 01 00 - 0B 01 00 - 0F
TX 0B 00 - 0B 0B 00 - 0F
RX 0C 00 - 0B 0C 00 - 0F
44.4.16 MO State
Table 83 BTS-supported codes
Code MO State Parameter Used by MO
00 Reset CF, IS, TRXC, RX, TF, TS, TX, DP
01 Started CF, TRXC
02 Enabled IS, RX, TF, TS, TX, DP
03 Disabled IS, RX, TF, TS, TX, DP
IWD-defined value range: 00 - 03