E21 Installation Manual
16
Name
Default value
Range
Description
mm/inch
0
0 or 1
0: Metric
1: inch
中文/English
0
0 or 1
0: Chinese
1: English
Release Time
0.3
0~99.99s
Interval between valid yield
signal and unloading output
when system starts.
Pulse Time
0.20
0.00~1.00s
The duration of the pulse
signal.
X-safe
10
0~9999.999mm
Keep low speed within this
range
Y-safe
5
0~9999.999mm
Keep low speed within this
range
Step delay
0.5
0~99.99s
Interval between valid step
change signal and system
executing step change.
Count Select
0
0 or 1
0: UDP, when the slider
leaves the UDP, the count
increases by 1.
1: EH, when one process
has been done, the count
increases by 1.
LDP Enable
0
0 or 1
0: Disable
1: Enable
Transducer
0
0 or 1
0: Vacon
1: Shihlin
X-tea.in
10
Between soft lim.
Input current X axis position
when teach enable.
Y-tea.in
10
Between soft lim.
Input current Y axis position
when teach enable.