EasyManuals Logo

Estun E21 User Manual

Estun E21
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
E21 Installation Manual
18
Name
Default value
Range
Description
Repeat Enable
0
1~99999999
0:disable
1:enable
Repeat Time
0.5
0~99.99s
Interval of back gauge
reposition when repeat
position
Mute Dis.
10
0~9999.999mm
Conversion distance between
high speed and low speed.
Motor lowers speed when
enter this range.
Stop Time
0.5
0~99.99s
Back gauge reaches advance
stop range. Due to inertia,
back gauge will not stop
immediately after motor stops.
The time for back gauge to
stop.
OT Time
0.5
0~99.99s
Interval between back gauge
reach over travel position and
input motor signal.
Drive Mode
1
0 or 1
0: common motor
1: single-frequency
converter
High freq.
100%
0~100
Frequency percent in the
high-speed mode. This value
is valid only when X drive
mode is set to frequency
converter.
High frequency = this value
× the fixed frequency
In general, the fixed frequency
is 50Hz.

Table of Contents

Other manuals for Estun E21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Estun E21 and is the answer not in the manual?

Estun E21 Specifications

General IconGeneral
BrandEstun
ModelE21
CategoryController
LanguageEnglish

Related product manuals