Emission measurement Perform emissions measurement
73
4. When the log boiler is ready for emissions mea-
surement, a message on the screen will indicate
this. The boiler is now operated at full load (or
partial load respectively) and the output
adjustment is blocked while doing so. Therefore,
the boiler output is not reduced. The control
system also ensures that heat is dissipated into the
heating system on a mandatory basis, if this is
possible.
Perform the emissions measurement now.
The doors on the log boiler may not be
opened during the emissions measurement.
Also, do not stoke the fire in the log boiler.
5. Switch the boiler back to normal mode after the
emissions measurement. To do this, press the
[Deactivate measurement] button in the
settings window. If you do not press this button, the
boiler will automatically switch back to normal
mode after some time.