26 OneTrack and OneTrack Backbone Planning and Installation Manual
Installation
WARNING: RISK OF ELECTRIC SHOCK! Cover the ends of OneTrack and
OneTrack Backbone with end caps.
AVERTISSEMENT : RISQUE DE CHOC ELECTRIQUE! Couvrez les extrémités
du OneTrack et du OneTrack Backbone avec des embouts.
WARNING:
• Per NEC article 410.151(A), lighting track fittings shall not be equipped
with general purpose receptacles. Do not attempt to connect power
tools, extension cords, appliances, or similar devices to the track. Only
install lighting track fixtures and fittings in the track.
• The track system is to be supplied by up to two branch circuits.
• Track does not support mounting by electrical cable.
CAUTION:
• OneTrack and OneTrack Backbone are to be installed by qualified
personnel only.
• It is the responsibility of the installer to ensure the electrical, mechanical
and thermal compatibility of the track system and the fittings.
• Material used for surface mounting must conform to building
regulations.
Tools Required
• If you will cut track:
‐ miter saw
‐ track trimming tool (ETC part number 7076A1004)
• #1 Phillips driver (handheld, not powered)