Models available EV3 MVC EVD MVC EV3K11 EVJ LCD
Digital outputs (triac; A res. @ 250 VAC)
triac 2
Digital outputs (open collector)
open collector 1
Communications ports
INTRABUS • • • •
RS-485 MODBUS • •
Other features
Clock • •
Buzzer • • •
Purchasing codes
- EV3 MVC: EV3934LM2 (no option)
EV3936LM2GF (2 triac + RS-485 MODBUS port + clock)
- EVD MVC: EVD934BM9MF
- EV3K11: EV3K11X0CT
- EVJ LCD:
Purchasing codes
Installation
mode
Power
supply
External
analogue
inputs
Digital
inputs
Incorporated
temperature
& humidity
sensor
Incorporated
Bluetooth
Low Energy
sensor
EVJD900N2VW
wall mounted
12 VAC/DC
1 no
no
no
EVJD900N2VWTX
1 no no
EVJD900N2VWIV 1 no yes
EVJD920N2VW 1 no
yes
no
EVJD920N2VWIV 1 no yes
EVJD902N9VP
ewall
mounted with
back-slot for
flush
mounting box
115... 230
VAC
2 2
no
no
EVJD902N9VPIV 2 2 yes
EVJD922N9VP 2 2
yes
no
EVJD922N9VPIV 2 2 yes
(1)
with RS-485 with INTRABUS communication protocol