Number Module /
Unit
Info Message Explanations / Remedies
and dry
them.
4. Put back the
chutes and
the mixer
(C, B, A).
5. Close the
powder unit.
S-100 Steam
module
Steam boiler is
heating...
This message occurs if the
steam boiler pressure is below
0.8 bar and the boiler starts
to heat to the nominal
value (e.g. in the morning
after switching on the coee
machine).
- -
S-101 Steam
module
Please switch o
the machine.
This message occurs if
the steam boiler has been
emptied or depressurized.
The coee machine has to be
switched o (main switch).
- -
S-102 Steam
module
Empty steam
boiler...
Contact service organisation. -
S-103 Steam
module
Depressurise
steam boiler...
Contact service organisation. -
S-104 Steam
module
Fill steam
boiler...
If the water level is lower than
the safety level the steam
boiler has to be lled.
Wait until the steam boiler is
lled.
- -
S-105 Steam
module
Rinse necessary.
The steam boiler
isn't allowed to
heat before the
machine is
rinsed.
After switching on the coee
machine, the steam boiler has
to wait until the rinse button
is pressed before it is allowed
to heat.
Press the rinse key in the
upper right corner (page 46).
Press the rinse key in the
upper right corner.
- -
S-106 Steam
module
Initialise, please
wait...
Wait until the initialisation
has nished.
- -
S-107 Steam
module
Steam boiler
security probe
problem.
Contact service organisation. -
S-108 CCI/CSI Interface not
detected. All
steam and hot
This message only occurs if
you use an external interface
(CSI or CCI).
- -
Troubleshooting