Number Module /
Unit
Info Message Explanations / Remedies
Consult the
rinse history for
more
information.
Check the
coee nozzle
and screens of
the right
brewing unit.
W-075 Brewing
module
The extraction
time left is too
high.
Please press
Continue to
start a rinse.
The extraction time is more
than 15 s too long three times
running.
To check if the machine
has a problem, a rinse will
be performed after pressing
Continue.
If the warning doesn't
disappear after the rinse,
login with super user access:
=> Consult the Rinse history
for more information.
=> Please contact your service
technician.
-
W-076 Brewing
module
The extraction
time right is too
high.
Please press
Continue to
start a rinse.
The extraction time is more
than 15 s too long three times
running.
To check if the machine
has a problem, a rinse will
be performed after pressing
Continue.
If the warning doesn't
disappear after the rinse,
login with super user access:
=> Consult the Rinse history
for more information.
=> Please contact your service
technician.
-
W-077 Brewing
module
The ow rate
during rinse left
is too high.
Consult the
rinse history for
more
information.
The ow rate during rinse on
the left side is higher than 15
ticks/s.
Contact service organisation.
-
W-078 Brewing
module
The ow rate
during rinse
right is too high.
Consult the
rinse history for
more
information.
The ow rate during rinse on
the right side is higher than 15
ticks/s.
Contact service organisation.
-