Number Module /
Unit
Info Message Explanations / Remedies
Consult the
rinse history for
more
information.
Check the
coee nozzle
and screens of
the right
brewing unit.
W-075 Brewing
module
The extraction
time left is too
high.
Please press
Continue to
start a rinse.
The extraction time is more
than 15 s too long three times
running.
To check if the machine
has a problem, a rinse will
be performed after pressing
Continue.
If the warning doesn't
disappear after the rinse,
login with super user access:
=> Consult the Rinse history
for more information.
=> Please contact your service
technician.
-
W-076 Brewing
module
The extraction
time right is too
high.
Please press
Continue to
start a rinse.
The extraction time is more
than 15 s too long three times
running.
To check if the machine
has a problem, a rinse will
be performed after pressing
Continue.
If the warning doesn't
disappear after the rinse,
login with super user access:
=> Consult the Rinse history
for more information.
=> Please contact your service
technician.
-
W-077 Brewing
module
The ow rate
during rinse left
is too high.
Consult the
rinse history for
more
information.
The ow rate during rinse on
the left side is higher than 15
ticks/s.
Contact service organisation.
-
W-078 Brewing
module
The ow rate
during rinse
right is too high.
Consult the
rinse history for
more
information.
The ow rate during rinse on
the right side is higher than 15
ticks/s.
Contact service organisation.
-
Troubleshooting
© Eversys S.A. Page 114 of 150 02.01.2023