Number Module /
Unit
Info Message Explanations / Remedies
W-086 Milk
module
Initial rinse of
milk system
hasn't been
performed yet.
Check if you are
logged out.
Make sure that you are being
logged out so that the init
rinse can start.
- -
W-087 Brewing
module
Top piston zero
position failure
left.
Please check the
left top piston
(screen and rod)
for coee
residue and
clean it.
Contact service organisation. - -
W-088 Brewing
module
Top piston zero
position failure
right.
Please check the
right top piston
(screen and rod)
for coee
residue and
clean it.
Contact service organisation. - -
W-089 Water
supply
Water line
pressure / ow
too low.
Please check the
water supply.
Contact service organisation. - -
W-090 Powder
unit
The fan of the
powder unit
doesn't run.
Contact service organisation. - -
W-091 Powder
unit
The left powder
dispenser of the
powder unit
doesn't run.
Check if it is
blocked.
Contact service organisation. -
W-092 Powder
unit
The right
powder
dispenser of the
powder unit
doesn't run.
Check if it is
blocked.
Contact service organisation. -
W-093 Powder
unit
The powder
pump of the
powder unit
doesn't run.
Contact service organisation. -