7.2 Parameter overview – setting ranges
7.2.1 MIG/MAG welding
Name
Display
Setting range
Code
Standard (ex
works)
Unit
Min.
Max.
Voltage correction
0
V
9,9
9,9
Wire feed speed, absolute (main program P
A
)
-
m/min
0,00
-
20,0
Gas nominal value (option GFE)
8,5
l/min
3,0
30,0
7.2.2 MMA welding
Name
Display
Setting range
Code
Standard (ex
works)
Unit
Min.
Max.
Arcforce
0
-40
-
40