Maintenance
EXAKT 35 / 50 Edition 04/09.2002
27
7.3 Cleaning the rollers
Clean and check the rollers after use and whenever the product
is changed.
Warning – Danger of injury when cleaning rollers with the
unit running!
There is an increased risk of injury at the roller gaps when
cleaning the rollers with the unit running.
Switch the unit off and, if necessary, disconnect it from main
power supply prior to cleaning the rollers with a cloth.
!" Use the hand-wheel to manually rotate the rollers.
!" When cleaning the rollers hold the cloth so that it cannot be
caught between the rollers and be pulled into the gap
Getting the cloth caught between the rollers can cause
damage to the rollers and/or the gears.
To clean the rollers:
!" Remove the guides and the scraper.
!" Attach the hand-wheel to the unit (Fig.
17/a) for manual roller rotation.
!" Clean the rollers using a clean cloth
and detergent or suitable solvent.
!" Remove the hand-wheel (Fig. 17/a)
after cleaning.
!" Do not spray the unit with or immerse it
in water, solvent or other liquid.
Fig. 17: Cleaning the rollers
a