5.1 Warm air distribution fan breakdown:
If the fan stops for any reason, the stove stops automatically to prevent overheating.
5.2 Fume extractor breakdown:
If the extractor stops, the electronic unit immediately blocks the supply of pellets.
5.3 Pellet feeding motor breakdown:
If the motor stops, the stove continues to operate until the minimum cooling level is reached.
5.4 Lighting failure:
If no flame develops during the lighting stage, the stove automatically makes another attempt to
light and if no flame comes this time either, the stove will show on the display
“ NO ACC”.
While attempting to light the stove , on the display you will read “ATTE” which means “WAIT”.
This function remembers that before lighting the stove , you must be sure that the burning pot,
must be completely free and clean.
5.5 Temporary power failure:
The appliance will re-light automatically after a brief power failure. There may be a minimum
quantity of smoke inside the house when there is no power for a period of 3 to 5 minutes.
THIS DOES NOT GIVE RISE TO ANY SAFETY RISK.
5.6 Electrical safety:
The stove is protected against violent power swings by a master fuse on the rear of the stove
(delayed 2A 250V).
5.7 Fume exhaust safety
An electronic pressure switch stops the loading screw in case the exhaust pipe is obstructed, or
in case the door remains opened for some minutes.
5.8 Safety for pellets overheating
In case of overheating inside the pellet hopper, this safety device stops the functioning of the stove,
the resetting is manual and must be done by a qualified technician.
ONLY FOR ECOLOGICA IDRO:
5.9 Plant pressure safety
A mechanical pressure sensor stops automatically eventually overpressure of the plant. The resetting
of this safety is manual and must be done by a qualified technician.
5.10 Safety for water boiling
In case of water shortage or a minimum water quantity, this safety stops the pellet feeding.
The resetting is manual and must be done by a qualified technician.
5 SAFETY DEVICES

Table of Contents

Other manuals for Extraflame DIVINA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extraflame DIVINA and is the answer not in the manual?

Extraflame DIVINA Specifications

General IconGeneral
BrandExtraflame
ModelDIVINA
CategoryStove
LanguageEnglish

Related product manuals