Appendix B: Technical Specifications
Summit Family Switches Hardware Installation Guide
470
Summit X480-48t with VIM2-SummitStack-V80 Module (DC Power Supply)
Nominal input ratings 48 V , 7.5 A
Input current 3.3 A @ 48 V (low-line)
2.6 A @ 60 V (high-line)
Heat dissipation 160 W, 546 BTU/hr
Power consumption 160 W, 546 BTU/hr
Summit X480-48t with VIM3-40G4X Module (DC Power Supply)
Nominal input ratings 48 V , 7.0 A
Input current 6.1 A @ 48 V (low-line)
4.0 A @ 60 V (high-line)
Heat dissipation 250 W, 854 BTU/hr
Power consumption 250 W, 854 BTU/hr
Safety Standards
North American Safety of ITE UL 60950-1 1st Ed., Listed Device (US)
CSA 22.2 #60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
European Safety of ITE EN 60950-1:2006
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
2006/95/EC Low Voltage Directive
International Safety of ITE CB Report & Certificate per IEC 60950-1:2006 + National Differences
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards EN 55022:2006 Class A
EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,8-2006 (Harmonics)
EN 61000-3-3 1995+A2:2005 (Flicker)
ETSI EN 300 386 v1.3.3, 2005-04 (EMC Telecommunications)
2004/108/EC EMC Directive
International EMC certifications CISPR 22: 2006 Ed 5.2, Class A (International Emissions)
CISPR 24:A2:2003 Class A (International Immunity)
EC/EN 61000-4-2:2001 Electrostatic Discharge, 8kV Contact, 15 kV Air,
Criteria A
EC/EN 61000-4-3:2006 Radiated Immunity 10V/m, Criteria
EC/EN 61000-4-4:2005 Transient Burst, 1 kV, Criteria A
IEC/EN 61000-4-5:2005 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC/EN 61000-4-6:2005 Conducted Immunity, 0.15-80 MHz, 10V/m unmod.
RMS, Criteria A
EC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%, 25 periods,
Criteria C
Country-specific VCCI Class A (Japan Emissions)
ACMA (C-Tick) (Australia Emissions)
CCC Mark
KCC Mark, EMC Approval (Korea)
Telecom Standards
ETSI EN 300 386:2001 (EMC Telecommunications)
ETSI EN 300 019 (Environmental for Telecommunications)
IEEE 802.3 Media Access
Standards
IEEE 802.3ab 1000BASE-T
Table 88: Summit X480 Series Switch Technical Specifications (Continued)