Command and Response Table for Matrix Switcher Commands (continued)
DTP CrossPoint 4K Series Matrix Switchers • Programming Guide 64
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
View and erase file directory
NOTE: The response to the View File Directory command differs, depending on whether the command is sent via an RS-232 or Telnet
connection or sent via a Web browser connection.
View file directory
RS-232 port and Telnet
E
DF
}
See below: List user-supplied files.
filename1•date/time•length
]
filename2•date/time•length
]
•
•
•
•
filenamen•date/time•length
]
# of•Bytes•Left
]]
View file directory
Web browser
E
DF
}
See below: List user-supplied files.
Var•file•=•new•array•();
File
•[1]•=•‘filename1,date1,filesize1‘;
File
•[2]•=•‘filename3,date3,filesize3‘;
•
•
•
•
File•[n]•=•‘filenamen,daten,filesizen‘;
File
•[n+1]•=•# of•Bytes•Left
Erase user-supplied Web page/files
E
filenameEF
}
Del•filename
]
Scaler Output Commands
Brightness
Set a specific brightness value
EX2!
*
X3)
BRIT
}
Brit
X2!
*
X3)]
Specify the brightness adjustment.
Increment brightness value
EX2!
+BRIT
}
Brit
X2!
*
X3)]
Increase the brightness setting by one.
Decrement brightness value
EX2!
–BRIT
}
Brit
X2!
*
X3)]
Decrease the brightness setting by one.
View the brightness value
EX2!
BRIT
} X3)]
Show the brightness setting.
Contrast
Set a specific contrast value
EX2!
*
X3)
CONT
}
Cont
X2!
*
X3)]
Specify the contrast adjustment.
Increment contrast value
EX2!
+CONT
}
Cont
X2!
*
X3)]
Increase the contrast setting by one.
Decrement contrast value
EX2!
–CONT
}
Cont
X2!
*
X3)]
Decrease the contrast setting by one.
View the contrast value
EX2!
CONT
} X3)]
Show the contrast setting.
Detail
Set a specific detail value
EX2!
*
X3)
HDET
}
Hdet
X2!
*
X3)]
Specify the detail adjustment.
Increment detail value
EX2!
+HDET
}
Hdet
X2!
*
X3)]
Increase the detail setting by one.
Decrement detail value
EX2!
–HDET
}
Hdet
X2!
*
X3)]
Decrease the detail setting by one.
View the detail value
EX2!
HDET
} X3)]
Show the detail setting.
Horizontal shift
Specify a value
EX2!
*
X3!
HCTR
}
Hctr
X2!
*
X3!]
Set the horizontal location of first active
pixel in output
X2!
.
Increment value
EX2!
+HCTR
}
Hctr
X2!
*
X3!]
Increment the value by one pixel (shift
the image to the right).
Decrement value
EX2!
–HCTR
}
Hctr
X2!
*
X3!]
Decrement the value by one pixel (shift
the image to the left).
View
EX2!
HCTR
} X3!]
Show the horizontal location of first
active pixel in output
X2!
.
NOTE: X2! = TP (scaled) and insertion output number 05 – 08
X3) = Picture adjustments 000 through 127 (064 = default)
X3! = Position and size ±10240 (Horizontal is specified from left, vertical from top, 0 is reported as positive [+])

Table of Contents