ShareLink Pro 500 • SIS Configuration and Control 35
Command ASCII Com-
mand
(Host to Device)
Response
(Device to Host)
Additional Description
Unit name
Set unit name/hostname
EX3)CN} Ipn
•
X3)]
Set unit name/hostname to
default
E
•
CN} Ipn
•
X3!]
Default = ShareLink-Pro-xx-xx-xx
(where xx-xx-xx is the last six digits
of the unique MAC address).
View unit name/hostname
ECN} X3)]
Ipn
•
X3)]
View unit name/hostname
(Verbose mode 2/3)
Information
Information request
(View unit information)
I/i
Inf*Frq X@
•
HdcpIX1$
•
HdcpOX1$
•
VmtX1*
•
AmtX1(
•
VolX2#]
Verbose mode 2/3:
Inf00*Frq X@
•
HdcpIX1$
•
HdcpOX1$
•
VmtX1*
•
AmtX1(
•
VolX2#]
Query firmware version
Q/q
X3@]
View firmware version
Query firmware and build
version
*Q/q
X3#]
View firmware version and build
version
Query internal temperature
E20STAT} X3$]
20StatX3$]
Query internal temperature
(Verbose mode 2/3)
Query model name
1I/i
<model name>]
Inf01*<model name>]
View model name
(Verbose mode 2/3)
Query model description
2I/i
<model description>]
Inf02*<model desc.>]
View model description
(Verbose mode 2/3)
Query part number
N/n
<part number>]
Pno<part number>]
View part number
(Verbose mode 2/3)
KEY:
X@ = Input signal
0 = No input signal detected 1 = Input signal detected
X1$ = HDCP status
0 = Not connected, 1 = Not HDCP Encrypted, 2 = HDCP Encrypted
X1* = Video mute status
0 = Unmute (default), 1 = Mute video, 2 = Mute sync
X1( = Audio mute status
0 = Unmute (default), 1 = Mute
X2# = Volume adjustment range
-100 to 0 = (default is -30dB)
X3) = Unit name
Alpha-numeric up to 63 characters. No blanks, spaces, or special
characters except hyphen (-).
X3! = Default unit name
Alpha-numeric name. ShareLink-Pro-xx-xx-xx (where xx-xx-xx
is the last six digits of the unique MAC address).
X3@ = Firmware version (Ex: 1.00)
X3# = Firmware version and build version (Ex: 1.00.0010)
X3$ = Internal temperature (2 digits, °C)