EasyManua.ls Logo

FAAC B614 - 5 Electronic Installation; Board E614; Components; E614 Board Technical Data

FAAC B614
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B614 29 532297 - Rev.D
5. ELECTRONIC INSTALLATION
F
ALWAYS DISCONNECT THE POWER SUPPLY before
working on the board. Turn power on only after
having made all the electrical connections and carried
out the preliminary start-up checks.
The board cover must never be removed unless the
board is to be replaced. No installation operation
requires the removal of the cover.
5.1 BOARD E614
4 E614 board technical data
Power supply voltage 115V~ +/-10% 50/60 Hz
Max power 150 W
Accessories output voltage 24 V
"
Max. accessories load 500 mA
Max. BUS 2easy accessories load 500 mA
Max. flashing light load 24 V
"
15 W
Ambient operating temperature -4 ° to +131 °F (-20 °C to +55 °C)
COMPONENTS
See figure 30
BOARD:
J1 Mains power supply terminal block
J3 BUS 2easy terminal block
J6 Inputs terminal block
J7 Connector for XF radio module
J8 Connector for battery backup
J10 Terminal block for external detector
LOOP1
J11 Connector for encoder
J13 Terminal block for external detector
LOOP2
J16 Terminal block for external flashing light
J18 Terminal block for the arm lights
J20 Terminal block for outputs
J21 Connector for integrated flashing light
J23 Connector for motor
F1 Board protection fuse (F1 = T5A UL approved)
DISPLAY Programming display
DL1 BUS 2easy ACTIVE LED
BOARD:
DL2 BUS 2easy “BUS MON“ diagnostic LED
DL3 “RADIO1” (OMNIDEC) LED
DL4 “RADIO2” (OMNIDEC) LED
DL5 Error / alarm LED
DL8
EMER status LED
DL9
STOP/FSW-CL status LED
DL10
CLOSE status LED
DL11
OPEN status LED
DL12
LOOP1 status LED
DL13
LOOP2 status LED