6. STARTUP
!
During operation there is a risk of cutting, crushing
or the total loss of hands due to the moving parts
inside the box.
If two barriers are installed in the following config-
uration
Master-Slave, before beginning the start up
of the Master, it is necessary to have configured the
Slave barrier (see the chapter § 9).
1. Check that the B614 manual release is not engaged
so that the arm can't be moved manually.
2. Power up the barrier (
Master barrier). The board
lights up and the display then comes on:
- firmware version (2 digits separated by a point)
-
SO flashing if a set-up or the automation status
is requested
3. Check the status of the LEDs at rest (see the chap-
ter § 10.1).
The BUS 2easy LEDs must be checked after the devices
have been registered.
4. Store the radio transmitter as needed (see the
chapter § 8.2).
5. Program E614 without performing the set-up.
!
For the barrier to work properly, set the parameter
cF dependent on the arm length.
6. Register the BUS 2easy devices, if they are installed
(see the chapter § 8.3).
7. Check the barrier's direction of travel (see the
chapter § 10.2).
8. Perform the set-up (see the chapter § 6.3).
9. If the Battery Backup is being used:
- Turn off power
- Connect the Battery Backup
- Switch on power to the system.
6.1 PROGRAMMING
BASIC PROGRAMMING
1. Press and hold down F until the first basic
function appears. (Each function is displayed
as long as F remains pressed).
F
2. Release: the value of the function appears
(default or programmed).
F
3. Use the
+
or
-
button to modify the value.
-
+
4. Press F to confirm the value displayed. Go
to the next function. The modified value
becomes effective immediately.
F
Proceed in the same way for all the functions. The last function
(
St) allows you to close the program.
5. In
St select Y or no using the
+
+/
-
buttons:
Y = save the new program
no = DO NOT save the new program
6. Press F to confirm and close the program. It returns to the
automation status view.
To exit from the programming mode at
any time:
press and hold down F and then
-
as well to
move directly to
St.