B614 49 532297 - Rev.D
10. DIAGNOSTICS
10.1 LEDS CHECK
LED STATUS IDLE
DL1 BUS
active
not active
DL2 BUS MON See BUS 2easy device
registration
DL3 RADIO1
active
not active
DL4 RADIO2
active
not active
DL5 Error/alarm “ERROR”
active
not active
DL8
EMER
not active
active
DL9 STOP
not active
active
DL10 CLOSE
active
not active
DL11
OPEN
DL12
LOOP1
active
not active
DL13
LOOP2
active
not active
In Master-Slave configuration see the chapter § 9.
10.2 DIRECTION OF MOVEMENT CHECK
1. Select parameter M1 in the Basic program-
ming. The display shows
--.
2. Keep the
button pressed. The display shows
oP and the barrier opens.
3. Keep the
button pressed. The display shows
cL and the barrier closes.
4. If the conditions in points 2 and 3 are not respect-
ed, invert the motor wires.
10.3 ENCODER OPERATION CHECK
1. Select parameter M1 in Basic Programming, the
display shows
--.
2. Keep the
button pressed. The display shows
oP and the barrier opens. The flashing point
between the two letters indicates that the encoder
is operating correctly.
3. Keep the
button pressed. The display shows
cL and the barrier closes. The flashing point
between the two letters indicates that the encoder
is operating correctly.
10.4 AUTOMATION SYSTEM STATUS
CHECK
The E614 display if not in the programming, shows a
code indicating the status the automation is in:
00
Closed
01
Open
02
Stationary then opens
03
Stationary then closes
04
In pause mode
05
Opening
06
Closing
07
Failsafe in progress
08
BUS 2easy device verification in progress
09
Pre-flashing and then opens
10
Pre-flashing and then closes
11
Opening in Emergency
10.5 CHECK FIRMWARE VERSION
When the display of the E614 is switched on, it shows
the following in succession:
- firmware version (2 digits separated by a point)
- automation system status
10.6 CHECK OF THE REGISTERED
BUS 2EASY DEVICES
1. Select parameter bu in Basic programming.
2. Press and hold the
button; the segments relative