35
36
37
B614 33 532297 - Rev.D
N
L
6 A
PE
N
L
AC MAIN
J1
XF 433-868
J7
MAIN SWITCH
TRAFFIC
LAMP
LIGHT
BEAM
COM
BLR
BLG
J18
J21
ENCODER
The encoder wire is connected from the factory.
The encoder must always be connected in order for
the automation system to operate.
ARM LIGHTS
See the chapters § 8.4 for the connection.
INTEGRATED FLASHING LIGHT
35See the chapter § 8.5 for the connection.
XF RADIO MODULE
36See the chapter § 8.2 for the activation.
MAINS SUPPLY AND EARTHING
!
Do not remove the grounding done in the factory.
37Connect the power cable to the main switch,
using PE, N, L terminals.
Use a standard AWG 14 tripolar cable (not supplied).