5.2 Operation in levels
General cooling parameters - parameter)(c
Parameters such as setpoints, hysteresis etc. can be set here.
Extended cooling parameters - (P parameter)
Setting of plant-specific functions such as agitator function, cooling start variant,
milk removal option, etc.
General cleaning parameters - (n parameter)
Parameters such as the run times of the rinses etc. can be set here.
Extended cleaning parameters - parameter)(r
Setting of plant-specific functions such as configuration of safety elements, level
detection, number of passes of individual etc.cleaning stages
Service parameters - (E parameter)
Displays the tank monitor parameters and counters
General tank monitor parameters - (h-parameter)
Determine whether and when are triggeredinformative alarms
Extended tank monitor parameters - (H parameter)
Determine whether and when are triggeredcritical alarms
Alarm configuration - (F parameter)
Here an individual behaviour can be assigned for each fault.
Configuration - (A parameter)
Determination / Parameterisation of the hardware configuration
I / O test parameters - (o parameter)
Is intended for commissioning the control system.
The working level is used for
operation and control in every-
day operation.
The is Gala-Kool Pro
parameterized in 10 different
parameter levels.
The subordinate parameter
levels are only entered after
entering a code in order to
avoid inadvertent adjust-
ment of the parameters.
General cooling parameters C parameter code: C212
Extended cooling parameters P parameter code: D345
General cleaning parameters n parameter code: B454
Extended cleaning parameters r parameter code: C567
Service parameter s E arameter p code: EA03
General tank monitor parameters h parameter code: 4711
Extended tank monitor parameters H parameter code: F94A
Alarm configuration F parameter code: FFFF
Configuration A parameter code: A384
I/O test parameters o. parameter code: 10E5
Working level
Page 11
5. Operation