Fabdec DARI-KOOL GALA-KOOL Pro - General Cleaning Parameters (n parameters)

Default Icon
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Working level
for normal daily operation
Range Default
Running times cleaning stage 0 (rinse out)
- hidden, if [r40] = 0
n01 Water intake time 0 .. 999 sec. 0
n02 Rinse out time with water intake 0 .. 999 sec. 60
n03 Drain time 0 .. 999 sec. 60
Running times cleaning stage 1 (pre-rinse 1)
- hidden, if [r41] = 0
n10 Water intake by feed container (displacement cleaning) 0 .. 6 0
n11 Water intake by level 1 0 .. 1 0
n12 Water intake by time 0 .. 999 sec. 70
n13 + circulation Additional water intake time 0 .. 999 sec. 20
n14 Main circulation time 0 .. 999 sec. 60
n15 Rinse out time 0 .. 999 sec. 0
n16 Drain time 0 .. 999 sec. 60
Running times cleaning stage 2 (pre-rinse 2)
- hidden, if [r42] = 0
n20 Water intake by feed container (displacement cleaning) 0 .. 6 0
n21 Water intake by level 1 0 .. 1 0
n22 Water intake by time 0 .. 999 sec. 70
n23 + circulation Additional water intake time 0 .. 999 sec. 20
n24 Main circulation time 0 .. 999 sec. 60
n25 Rinse out time 0 .. 999 sec. 0
n26 Drain time 0 .. 999 sec. 60
Running times cleaning stage 3 (main rinse 1)
- hidden, if [r43] = 0
n30 Water intake by feed container (displacement cleaning) 0 .. 6 0
n31 Water intake by level 1 0 .. 1 0
n32 Water intake by time 0 .. 999 sec. 70
n33 + circulation Additional water intake time 0 .. 999 sec. 40
n34 Main circulation time 0 .. 999 sec. 180
n35 Rinse out time 0 .. 999 sec. 0
n36 Drain time 0 .. 999 sec. 70
Switch to level
“General cleaning parameters”
See section 8.1.
n parameters
Code: B454
Applies to all “Water intake
by level 1" situations:'
0 = deactivated
1 = activated
General cooling parameters code: C212
Extended cooling parameters code: D345
General cleaning parameters code: B454
Extended cleaning parameters code: C567
Service parameter s code: EA03
General tank monitor parameters code: 4711
Extended tank monitor parameters code: F94A
Alarm configuration code: FFFF
Configuration code: A384
I/O test parameters code: 10E5
8.4 Level “General cleaning parameters” (n parameters)
8. Setting of parameters
For all „water intake by
feed container“ the
following applies:
0 = deactivated
1..6 = Number of
repetitions
Page 51