The monitoring module ESVAW-002-A is used to monitor max. 2 agitator agitator
motors in milk cooling tanks. The motors can be switched on or off directly via agitator
the module via the integrated relays. Thus, e.g. n a cooling tank control no relay for o
switching the motors are occupied.agitator
ESVAW-002-A
The agitator monitoring module ESVAW-003-A is designed to monitor a three-phase
AC motor with 400V AC.
ESVAW-003-A
The monitoring module is determining the power input independently for each
connected motor and hereof it will be deduced whether the respective motor rotates
and whether it runs with or without load so that a defective stirring wing can be de-
tected for example.
The module has to be configurated in parameter [A71]
For different applications different monitoring modules are available:2 agitator
For the correct installation please pay attention to the supplied documentation of the
respective module.