critical + informative alarm
(press RESET button)
Critical + informative alarm - Milk must not be taken out.
Green = flashing
Red = flashing
after RESET
Green = flashing
Red = on
The driver s to the and checks the tank monitor.goe Gala-Kool Pro
Green and red LEDs are flashing, an error code blinks in the display
The driver informs the farmer -> Farmer and driver investigate the cause of the
critical and informative alarms. (The critical alarm codes are taken from the
display and identified using the fault table. ) See section 8.9
The farmer and driver then decide together whether the milk can be transferred
to the tanker, despite the alarm.
The farmer first presses the RESET button to cancel the critical alarm.
The farmer presses the RESET button again -> the red LED is lit continuously.
The farmer then cancels the informative alarm -> the green LED turns off.
Once the tank is emptied the washing process must be started.
It is only when the cleaning cycle is active for at least 10 minutes that the tank moni-
tor resets all critical alarms.
critical + informative alarm
after second RESET
Green = off
Red = on
critical + informative alarm
(press RESET button)
7. Tank monitor and general fault handling
Page 33