Range Default
c25 Maximum continuous stirring period 0 .. 999 min. 30
in mode ‚continuous stirring‘
Setting of maximum continuous stirring period.
0: indefinite stirring
)(to end, the OFF button must be pressed
1..999: max. stirring period in minutes
Sensor correction adjustment Range Default
c90 Display actual temperature sensor 1
c91 Sensor correction sensor 1 10 .. 10 K
A correction can be applied to the value measured
by the sensor. Then applies it cumulatively
throughout the entire measurement range.
c92 Display actual temperature sensor 2
(hidden if A50 = 0)
c9 Sensor correction3 sensor 2 -10 .. 10 K
(hidden if A50 = 0)
A correction can be applied to the value measured
by the sensor. Then applies it cumulatively
throughout the entire measurement range.
Software version
c98 Installed software version
The software version installed is shown to help
service technicians.