Working level
for normal daily operation
Switch to level
“I / O test parameters”
See section 8.1.
o parameters
Code: 10E5
Test relay outputs Range Default
Switched-on relays remain switched on until they are
reset manually.
o.1 Test relay 1 0 .. 1 0
o.2 Test relay 2 0 .. 1 0
o.3 Test relay 3 0 .. 1 0
o.4 Test relay 4 0 .. 1 0
o.5 Test relay 5 0 .. 1 0
o.6 Test relay 6 0 .. 1 0
o.7 Test relay 7 0 .. 1 0
o.8 Test relay 8 0 .. 1 0
o.9 Test relay 9 0 .. 1 0
o.10 Test relay 10 0 .. 1 0
o.11 Test relay 11 0 .. 1 0
o.12 Test relay 12 0 .. 1 0
o.14 Test of external relay 1 0 .. 1 0
o.15 Test of external relay 2 0 .. 1 0
o.16 Test of external relay 3 0 .. 1 0
o.17 Test of external relay 4 0 .. 1 0
o.18 Test of external relay 5 0 .. 1 0
0: Off
1: On
Meaning of the parameters
All inputs and outputs of the individual components can be tested in this parameter
level. For this purpose the corresponding relays are set to 'I' or '0'.
N : However, the two relays for the supply of acid and alkaline detergents are locked B
against each other since never acid and alkaline detergents may enter the tank never
together!
This operating level is NOT reset automatically!
General cooling parameters code: C212
Extended cooling parameters code: D345
General cleaning parameters code: B454
Extended cleaning parameters code: C567
Service parameter s code: EA03
General tank monitor parameters code: 4711
Extended tank monitor parameters code: F94A
Alarm configuration code: FFFF
Configuration code: A384
I/O test parameters code: 10E5
8.11 “I / O test parameters” (o. parameters)Level
8. Setting of parameters