24 < < < <
6. COMMISSIONING (functional checks)
Note: After installation, make sure that the gaslines from gas connection to
the gas control are checked for gas leakes before the appliance is used for
the first time!
6.1. Check pilot ignition
1) Push in and turn the control knob (A) anticlockwise to the setting
(small flame). You will hear a tick meaning there is ignition. Hold the
knob in and wait for a few seconds while the air is purged.
2) Bring the knob back in the start position and turn the knob several
times to the
position. Check that the pilot has lit.
3) Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
4) Release the knob. The pilot should remain alight.
6.2 Functional burner check
1) Turn knob (B) to max. clockwise.
2) Turn the knob (A) more anticlockwise to the position
(large
flame). Now it is possible to light the main burner.
3) Turn knob B anticlockwise to max. The main burner should light.
fig. 21: Gas control block front