28 < < < <
8. SERVICING
To ensure safety, efficient operation of the appliance, it is necessary to
carry out routine servicing at regular intervals. It is recommended, that the
fire is inspected/serviced by a competent person at least once a year.
Important: Turn off the gas supply before commencing any servicing. Always
test for gas soundness after refitting the appliance.
8.1 Routine annual servicing
1) Clean (if necessary):
• the pilot system;
• the burner;
• the combustion chamber;
• the glass.
2) Check the log lay and replace the embers (if applicable).
3) Do the functional test as described at 6.2.
4) Check the flue system and do a spillage test as described at 6.3.
Note
• The logs contain Refractory Ceramic Fibre which when cut or broken
open can irritate the skin and the respiratory tract. Always wear gloves,
do not blow dust into air.
• Clean up using a vacuum cleaner equipped with a HEPA filter.
• Never place extra elements of any kind into the combustion chamber.
• To guarantee good combustion, the log set may only be installed in the
way specified by Faber International BV. Any other arrangement can lead
to soot on logs or window.