> > > > 35
Country UK/IRL UK/IRL UK/IRL UK/IRL
Cat. II2H3+ II2H3+ II2H3+ II2H3+
Appliance Silence / Feeling
/ Sense
Silence / Feeling
/ Sense
Serene Serene
logburner logburner logburner logburner
Appliance type
B11BS B11BS
B11BS
B11BS
Reference gas
G20 G31
G20
G31
Input (nett) [kW]
6,9 6,5
6.2
6.2
Efficiency class
2 2
2
2
Inlet pressure [mbar]
20 37
20
37
Gas Rate (15º C and
1013 mbar) m3/h
0,72 0,24
0.65
0.24
Reference burner
pressure
[mbar]
8 15,4
10.5
21
Injector size [mm]
2x1,60 1x 1,50 3 x 1,00
3 x 1.40
3 x 0.90
reduced input
restrictor
[mm]
1,8 1,1
1.80
1.00
Pilot assembly
Type
SIT 160 SIT 160
SIT 160
SIT 160
code
Nr 51 Nr 30
Nr 51
Nr 30
Flue size (min)
100mm 100mm
100mm
100mm
Min Flue height
3 m 3 m
3 m
3 m
Gas control
GV36-C5AOEHC68M
GV36-C5AODHC68M
GV36-C5AODHC68M GV36-C5AODHC68M
Remote control
adapter
230VAC/50HZ/5VA 230VAC/50HZ/5VA
N.A.
N.A.
Voltage adapter [V]
4,5 4,5
1 x 9V 1 x 9V
Batteries RC
2 x LR03 Alkaline 2 x LR03 Alkaline 2 x LR03 Alkaline 2 x LR03 Alkaline
Gas connection
8mm nut & olive 8mm nut & olive 8mm nut & olive 8mm nut & olive
Dimensions: see
table 1