Operation Page 27/28
6.14 Menu structure with factory setting
Start
Display
Main
Menu
Level 2
Level 3
Possible values
Factory setting
Bar graph presentation
Relay status
Relays
K1
S-P On
S-P Off
On Delay
Off Delay
Alarm
0,1 … 99,9 %
0,1 … 99,9 %
0 … 255 s
0 … 255 s
ON/OFF
94.0 %
95.0 %
0 s
0 s
ON
K2
S-P On
S-P Off
On Delay
Off Delay
Alarm
0,1 … 99,9 %
0,1 … 99,9 %
0 … 255 s
0 … 255 s
ON/OFF
94.0 %
95.0 %
0 s
0 s
OFF
In the case of the UM-O and UM-O Ex versions, K1 and K2
are set together and a password is required.
S-P On
0,1 … 98,9 %
< S-P Off
94.0 %
S-P Off
0,2 … 99,0 % &
> S-P On
95.0 %
On Delay
Off Delay
Alarm
0 … 255 s
0 s
ON
0 s
0 s
ON
K3
S-P On
S-P Off
On Delay
Off Delay
Alarm
0,1 … 99,9 %
0,1 … 99,9 %
0 … 255 s
0 … 255 s
ON/OFF
74.9 %
75.1 %
0 s
0 s
OFF
K4
S-P On
S-P Off
On Delay
Off Delay
Alarm
0,1 … 99,9 %
0,1 … 99,9 %
0 … 255 s
0 … 255 s
ON/OFF
49.9 %
50.1 %
0 s
0 s
OFF
K5
S-P On
S-P Off
On Delay
Off Delay
Alarm
0,1 … 99,9 %
0,1 … 99,9 %
0 … 255 s
0 … 255 s
ON/OFF
24.9 %
25.1 %
0 s
0 s
OFF