Power supplies
94
2.
POWER SUPPLIES
Regenerative regulated power supplies
88
DDS
HARDWARE
Ref.1310
The following table shows the values for gap, tightening torque, sections
of the screws and other data of the plug-in connector for X5.
X6 connector
The screwed-on 7-pin Phoenix connector with screw (5.00 pitch) that the
RPS power supply has on its face plate for controlling the module.
A 1.25 A fuse protects the internal circuits.
The following table shows the values for gap, tightening torque, sections of
the screws and other data of the plug-in connector for X6.
T. H2/35 Data of the plug-in connector for X5.
Connector data
RPS-80
RPS-75
RPS-45
RPS-20
Nr of poles 2 2
Gap (mm) 5.00 5.00
Min/max tightening torque (N·m) 0.5/0.6 0.5/0.6
Screw thread M3 M3
Min./max. section (mm²) 0.2/2.5 0.2/2.5
Rated current In (A) 12 12
Wire data
Length to strip (mm) 7 7
F. H2/49
Connector X6. Control.
NOTE. Remember that the internal circuits of PS-65A non-regenerative
power supplies must be powered by an auxiliary 24 V DC power supply,
“APS-24”; that's why its control connector has three terminals more than
connector X6 of the RPS.
T. H2/36 Data of the plug-in connector for X6.
Connector data
RPS-80
RPS-75
RPS-45
RPS-20
Nr of poles 7 7
Gap (mm)
5.00 5.00
Min/max tightening torque (N·m)
0.5/0.6 0.5/0.6
Screw thread M3 M3
Min./max. section (mm²)
0.2/2.5 0.2/2.5
Rated current In (A)
12 12
Wire data
Length to strip (mm)
77
(Phoenix,
5.08 mm)
X6
Error Reset
GND
System Speed Enable
System O.K.
(Relay contact N.A)
321
X6
PWM Enable
RPS-