EasyManuals Logo

Faller 180725 User Manual

Faller 180725
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
47
Presetting servos
ANLAGENBAU
EN
CV Description Range Default
setting
»Servo 1« port
120 HighByte Address 1 0-8 0
121 LowByte Address 1 0-255 1*
122 Hold position “red” Address 1 0-127 30
123 Hold position “green” Address 1 0-127 95
124 Positioning time 0-255 40
125 Rocking amplitude Hold position “red”
Address 1
0-127 0
126 Rocking time Hold positionred Address 1 0-255 0
127 Rocking amplitude Hold position “green”
Address 1
0-127 0
128 Rocking time Hold position “green
Address 1
0-255 0
160 HighByte Address 2 0-8 0
161 LowByte Address 2 0-255 0
162 Hold position “red” Address 2 0-127 0
163 Hold position “green” Address 2 0-127 0
»Servo 2« port
130 HighByte Address 1 0-8 0
131 LowByte Address 1 0-255 3*
132 Hold position “red” Address 1 0-127 30
133 Hold position “green” Address 1 0-127 95
134 Positioning time 0-255 40
135 Rocking amplitude Hold position “red”
Address 1
0-127 0
136 Rocking time Hold positionred Address 1 0-255 0
137 Rocking amplitude Hold position “green”
Address 1
0-127 0