48
Presetting servos
ANLAGENBAU
EN
CV Description Range Default
setting
138 Rocking time Hold position “green”
Address 1
0-255 0
170 HighByte Address 2 0-8 0
171 LowByte Address 2 0-255 0
172 Hold position “red” Address 2 0-127 0
173 Hold position “green” Address 2 0-127 0
»Servo 3« port
140 HighByte Address 1 0-8 0
141 LowByte Address 1 0-255 5*
142 Hold position “red” Address 1 0-127 30
143 Hold position “green” Address 1 0-127 95
144 Positioning time 0-255 40
145 Rocking amplitude Hold position “red”
Address 1
0-127 0
146 Rocking time Hold positionred Address 1 0-255 0
147 Rocking amplitude Hold position “green”
Address 1
0-127 0
148 Rocking time Hold position “green
Address 1
0-255 0
180 HighByte Address 2 0-8 0
181 LowByte Address 2 0-255 0
182 Hold position “red” Address 2 0-127 0
183 Hold position “green” Address 2 0-127 0
»Servo 4« port
150 HighByte Address 1 0-8 0
151 LowByte Address 1 0-255 7*
152 Hold position “red” Address 1 0-127 30