Maintenance - 2000h
4812163801.pdf 2019-04-30
Replacing the urea pump filter
Fig. Urea tank space
1. Urea pump
1
The urea pump is located on the right side of the
machine, beside the urea tank.
2
2. Service hatch (urea pump)
The filter is located in the bottom of the unit.
To reach the filter, undo the lid with a 27 mm socket
and remove the filter with the tool supplied with the
filter spare.
Replace with the new filter and remount the lid with a
torque of 20 Nm.
Hand in the filter to an environment-friendly waste
disposal station.
Hand in the filter to an environment-friendly waste
disposal station.