Chapter 6 Description of Operations
PAGE 6-66
Rate
D-No. 300 Rate 1 Low Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
The low limit value of the slope of torque vs. angle between the two points of D-No. 112 [Rate 1
Start Torque] ~ D-No. 113 [Rate 1 End Torque] is set. A judgment is made at the point at which
D-No. 113 [Rate 1 End Torque] is attained.
D-No. 301 Rate 1 High Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
The high limit value of the slope of torque vs. angle between the two points of D-No. 112 [Rate 1
Start Torque] ~ D-No. 113 [Rate 1 End Torque] is set. A judgment is made at the point at which
D-No. 113 [Rate 1 End Torque] is attained.
D-No. 302 Rate 2 Low Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
The low limit value of the slope of torque vs. angle between the two points of D-No. 114 [Rate 2
Start Torque] ~ D-No. 115 [Rate 2 End Torque] is set. A judgment is made at the point at which
D-No. 115 [Rate 2 End Torque] is attained.
D-No. 303 Rate 2 High Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
The high limit value of the slope of torque vs. angle between the two points of D-No. 114 [Rate 2
Start Torque] ~ D-No. 115 [Rate 2 End Torque] is set. A judgment is made at the point at which
D-No. 115 [Rate 2 End Torque] is attained.
D-No. 304 Rate 3 Low Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
The low limit value of the slope of torque vs. angle between the two points of D-No. 116 [Rate 3
Start Torque] ~ D-No. 117 [Rate 3 End Torque] is set. A judgment is made at the point at which
D-No. 117 [Rate 3 End Torque] is attained.
D-No. 305 Rate 3 High Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
The high limit value of the slope of torque vs. angle between the two points of D-No. 116 [Rate 3
Start Torque] ~ D-No. 117 [Rate 3 End Torque] is set. A judgment is made at the point at which
D-No. 117 [Rate 3 End Torque] is attained.
* To input a negative value for any of D-No. 300 ~ D-No. 305, move the cursor (flashing number) at
the DATA indication part to the position of “P” and then press the “▲” or “▼” switch to make “-“ be
indicated at the cursor position.