Chapter 9 External Interface
PAGE 9-2
9-1 Common specifications
9-1-1 Fieldbus I/O signal specifications
HFC3000 [PLC HFC3000]Input signal specification
The input signal fixed layout.
No.
Bit
Singnal Name
Conne
ction
Contents
IN
No.01
IN
Word
No.01
0bit
0bit
Not USED
NO
Always off.
1bit
1bit
Not USED
NO
Always off.
2bit
2bit
Not USED
NO
Always off.
3bit
3bit
Not USED
NO
Always off.
4bit
4bit
BANK
NO
Fieldbus message bank reshuffling BIT.
In the case of CC-Link the output top position of
the message Can change it.
5bit
5bit
Not USED
NO
Always off.
6bit
6bit
RESET
NO
Resets to the initial condition
Clear ID data
7bit
7bit
Not USED
NO
Always off.
IN
No.02
8bit
0bit
Not USED
NO
Always off.
9bit
1bit
Not USED
NO
Always off.
10bit
2bit
Not USED
NO
Always off.
11bit
3bit
Not USED
NO
Always off.
12bit
4bit
Work Select Bit0
NO
Select fastening pattern.
Select the Parameter No.1~64 at Work Select
0~5.
13bit
5bit
Work Select Bit1
NO
14bit
6bit
Work Select Bit2
NO
15bit
7bit
Work Select Bit3
NO
IN
No.03
IN
Word
No.02
0bit
0bit
STOP
NO
Emergency stop
1bit
1bit
RESET
NO
Resets to the initial condition
(Clear ID data)
2bit
2bit
REVERSE
NO
Spindle will reverse(CCW) while active
3bit
3bit
START
NO
Starts fastening cycle
4bit
4bit
PROGRAM
NO
Bypass the unit
5bit
5bit
SELF CHECK OFF
NO
Disables self-check function
6bit
6bit
Not USED
NO
Always off.
7bit
7bit
Not USED
NO
Always off.
IN
No.04
8bit
0bit
Not USED
NO
Always off.
9bit
1bit
Not USED
NO
Always off.
10bit
2bit
Not USED
NO
Always off.
11bit
3bit
Work Select Bit5
NO
Work Select 5.
12bit
4bit
BATCH OK RESET
NO
Batch resets to the initial condition
13bit
5bit
Work Select Bit4
NO
Work Select 4.
14bit
6bit
Not USED
NO
Always off.
15bit
7bit
Not USED
NO
Always off.