Chapter 6 Description of Operations
PAGE 6-69
D-No.405 Reverse 1 Speed [rpm]
Setting range: Minimum tool rotation speed to maximum tool rotation speed
The speed during reverse operation is set.
This is the reverse speed at which rotation is performed while the REV. switch of the indicator is
pressed.
This is also the speed used in D-No. 002 [Fastening Option]: “Reverse before Fastening.”
D-No.406 Reverse Speed between 1-2 Step [rpm]
Setting range: Minimum tool rotation speed to maximum tool rotation speed
The speed during reverse operation is set.
This is the speed used in D-No. 006 [Fastening Interrupt Operation]: “Reverse Between 1-2 Steps
ON.”
D-No.407 Reverse Speed between 2-3 Step [rpm]
Setting range: Minimum tool rotation speed to maximum tool rotation speed
The speed during reverse operation is set.
This is the speed used in D-No. 006 [Fastening Interrupt Operation]: “Reverse Between 2-3 Steps
ON.”
D-No.410 1 Pulse Reverse Speed [rpm]
Setting range: Minimum tool rotation speed to maximum tool rotation speed
This is the speed used in D-No. 005 [After Fastening Operation]: “1 Pulse Reverse.”