Chapter 6 Description of Operations
PAGE 6-22
Similar operations can be performed from “ErASE,” with “021” indicated in the D-No. indication part,
to erase all fastening result record stored in the controller.
Be careful in executing erasing operation because data cannot be
recovered after the fastening result record is erased.
Fastening Result Record Erasing Operation Procedure
1. When the controller is in the PROGRAM mode, make “ErASE,” with “SYS” indicated in the WORK
indication part and “021” indicated in the COUNT/D-No. indication part, be indicated and then press
“SET.
2. Press the [▲] or [▼] switch to select “SinGLE” and then press “SET.”
3. After the indication at the DATA indication part changes to “ErASE YES,” press the [SET] switch within
2 seconds.
4. When the erasing of the fastening result record is started, “ErASE” in the DATA indication part flashes
for a few seconds and the flashing stops when the erasure is completed.
CF Card Formatting Operation
1. When the controller is in the PROGRAM mode, make “ErASE,” with “SYS” indicated in the WORK
indication part and “021” indicated in the COUNT/D-No. indication part, be indicated and then press
“SET.
2. Press the [▲] or [▼] switch to select “CF” and then press “SET.”
3. After the indication at the DATA indication part changes to “ErASE YES,” press the [SET] switch within
2 seconds.
4. When the formatting of the CF card is started, “ForMAT” in the DATA indication part flashes for a few
seconds.
5. If formatting succeeds, “SuccES” is indicated in the DATA indication part for 3 seconds (CF ACCESS lights up in
green).
6. If formatting fails, “FAILEd” is indicated in the DATA indication part for 3 seconds (CF ACCESS lights up in red).
Formatting
of CF Card
Erasure of
Fastening
Result Record
Canceled if not operated for 2 seconds.
Canceled if not operated for 2 seconds.
SinGLE
CF