Audio setting
After performing of changes please don’t forget click on „Save“.
Speaker volume + Microphone gain amplification setting
ECHO limiter it is designed for Echo cancellation which is created by distortion
of loud signal.During standard door entry call is working automatic
adaptive echo canceller which cancel the echo after cca 3 seconds of
talk and call is full duplex. The setting is : High intensity signals coming
from phone to speaker of door entry are distorted and automatic echo
canceller cant process them. This level of treshold you setup (in %).
How much should be reduced signal returning through microphone
input is adjusted by attenuation. Delay of returning signal is adjustable
by samples amount.
Tone here you select acoustical signalling of different door entry status.
Options are: - None, this status will not be signalling