13 Technical data
Controller CECC-X-M1-...
Operating voltage [X1, X5] [VDC] 19.2 … 30
Operating voltage [X21] [VDC] 19.2 … 50
Current consumption nominal at 24 VDC [mA] 200
Integrated brake chopper
Voltage limitation switch-on
threshold
[V] Operating voltage [X21] +2.0
Voltage limitation switch-off
threshold
[V] Operating voltage [X21] +0.5
Nominal power [W] 18
Continuous power [W] 5
Pulse power with pulse frequency
1 Hz (switch-on duration 10 %)
[W] 50
Braking resistor [Ω] 15
Protection against incorrect polarity No
Certification RCM
CE marking è Declaration of conformity
è www.festo.com/sp
in accordance with EU EMC Direct
ive
1),2)
USB cable length [m] 3
Motor cable length [m] 3
Other cable lengths [m] 10
Degree of protection IP20
Protection class III
Vibration and shock resistance (in ac
cordance with IEC/EN 60068-2-6)
SL1
3)
Mass storage devices
Supported types microSD, microSDHC, microSDXC,
USB
Capacity [GByte] 32
File system FAT32
1) The product is intended for use in industrial environments.
Measures for interference suppression may need to be implemented in residential areas.
2) The product is classified in zone A in accordance with EN 61131-2:2007.
3) è13.2 Explanation on vibration and shock – severity level